Recommend this page
image

System green

Showing the way

Real-time fluorescence imaging with the ENDOCAM Logic 4K platform

Richard Wolf's System green is an outstanding real-time ICG/NIR fluorescence imaging solution that meets the highest standards in endoscopic imaging. Indocyanine green (ICG, available as Verdye in many regions*) is a tricarbocyanine dye that fluoresces when used with an NIR camera system, allowing anatomical structures to be visualized.

ICG/NIR fluorescence imaging has become one of the most valuable techniques in minimally invasive surgery. Applications include intraoperative assessment of visceral perfusion (e.g. in bowel anastomosis), visualization of bile duct structures in fluorescence cholangiography and lymph node mapping in oncological surgery (e.g. visualizing sentinel lymph nodes in lymphadenectomy).

*Diagnostic Green is a leading global supplier of high-quality fluorescence products, including ICG. Full prescribing information for Verdye is available at: https://diagnosticgreen.com/row/product-information/

How fluorescence works

After administration, ICG enters the bloodstream, binds immediately to plasma proteins and circulates throughout the vascular system. The absorption spectrum of ICG (indocyanine green, Verdye, Diagnostic Green) is in the near-infrared (NIR) range: ICG absorbs light between 600 nm and 900 nm and emits fluorescence between 800 nm and 850 nm. An ICG/NIR camera system such as System green is used to visualize the ICG fluorescence, so it can be detected and visualized during surgery. NIR light allows surgeons to see structures more clearly.

System overview

ENDOCAM Logic 4K camera controller

The ENDOCAM Logic 4K offers endoscopic imaging in native 4K/UHD resolution and provides additional ICG/NIR image information in two different special imaging modes.

  • Richard Wolf special imaging modes:
  • greenICG (white light image with ICG overlay)
  • greenICG pure (grayscale image with ICG overlay)
  • High-resolution endoscopic images in sharp 4K/UHD quality
  • ICG-ready: existing units can easily be upgraded with a software update
ENDOCAM Logic 4K
ENDOLIGHT LED green
  • Powerful laser-free LED light source for perfect illumination in ICG/NIR and white light endoscopy
  • Automatic adjustment of NIR and white light intensity for detailed fluorescence imaging results, regardless of ICG concentration
  • New LED technology for a longer service life (up to 15,000 hours), reducing service and operating costs
  • Almost silent for a pleasant, quiet working environment
  • Compatible with the core nova OR integration system
Logic camera head (green)
  • For the ENDOCAM Logic platform
  • Also suitable for white light endoscopy without restriction
  • Digital image processing and signal transmission with a powerful dedicated NIR sensor for high fluorescence sensitivity
  • Extremely light and ergonomic for easy handling
  • Integrated lens designed for laparoscopy (f = 24 mm)
PANOVIEW ULTRA telescopes

A new fiber design and an especially bright lens system ensure sharp images and a longer service life.

  • 4K/UHD telescopes for bright, sharp, precise images
  • Optimized for ICG/NIR applications
  • Also suitable for standard white light endoscopy
  • Natural color visualization in white light mode and in the System green mode greenICG
Fused fiber light cable

Fused fiber light cables meet the highest standards in endoscopy.

  • High temperature resistance
  • Much longer service life
  • Easier to handle thanks to improved flexibility and steel kink protection
  • Higher efficiency, recommended for 4K systems
  • High light transmission for even illumination
ICG information

Indocyanine green (ICG, known as Verdye, Diagnostic Green)

Indocyanine green (ICG) is a tricarbocyanine dye that is both hydrophilic and lipophilic. Before use, the powder must be reconstituted with water for injection. Verdye is suitable for intravenous (i.v.) injection via injection needle, central or peripheral catheter or cardiac catheter. After i.v. injection, ICG binds rapidly to plasma proteins, with beta-apolipoprotein B as the main carrier (95%), and remains in the blood vessels.

ICG is cleared completely by the liver and excreted in the bile. ICG is not metabolized.

Technical data

  • Well tolerated*
  • Excellent safety
  • Cleared completely by the liver
  • Half-life of 3–4 minutes
  • Binds rapidly to plasma proteins
  • No significant extrahepatic or enterohepatic circulation

*Adverse reactions: injection of indocyanine green preparations is known to cause nausea and allergic reactions in very rare cases (< 1/10,000).

For full prescribing information for Verdye,please contact

PANOVIEW ULTRA augmented reality app

Explore a 3D model of System green with the augmented reality app.

Here's how it works:

1. Download the 'RIWO AR' app to your smartphone or tablet.

2. Launch the app on your device.

3. Scan the image on the right with the app.

Downloads
Catalog
Surgery
19MB PDF
Catalog
Imaging
10MB PDF
Brochure
System green
7MB PDF
Questions?We are ready to help!
Customer Service
hongkong@richard-wolf.com